Open Access

Tableau 5

Épaisseur moyenne de couche oxydée du PEI déterminée par micro-indentation, spectroscopie IRTF ou microscopie optique après différentes durées d’exposition dans l’air à 220 et 250 °C.

Average thickness of oxidized layer of PEI determined by micro-indentation, FTIR spectrophotometry or optical microscopy after different durations of exposure in air at 220 and 250 °C.

T (°C) t (h) lox (µm)
220 429 275 ± 25
  667 400 ± 50
  1270 750 ± 50
  1985 750 ± 50
250 94 225 ± 25
  670 350 ± 75
  1273 490 ± 60
  1966 550 ± 50

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.