Issue |
Matériaux & Techniques
Volume 99, Number 1, 2011
Numéro thématique : Corrosion - Défis et avancées scientifiques et techniquesTopical Issue: Corrosion: scientifical and technical challenges and progress |
|
---|---|---|
Page(s) | 51 - 64 | |
DOI | https://doi.org/10.1051/mattech/2011004 | |
Published online | 24 February 2011 |
La solution des armatures inox pour la durabilité du béton armé : une revue des propriétés
Stainless steel concrete reinforcement: a bibliographic review
1
Ugitech, Ingénieur corrosion, Centre de Recherches, Avenue Paul
Girod, 73403
Ugine,
France
e-mail : eric.chauveau@ugitech.com; christian.trombert@ugitech.com
2
Inox Consulting, Consultant, 281 route de Thônes,
74210
Faverges,
France
e-mail : bernard.demelin@orange.fr
3
CIM Béton, Ingénieur conseil, 7 place de la Défense,
92974
Paris La Défense Cedex,
France
Reçu :
25
Juin
2010
Accepté :
4
Janvier
2011
Le béton armé d’acier inoxydable peut constituer dans certains environnements très agressifs (pont en bord de mer, ...) une solution efficace aux problèmes de fissuration du béton par l’expansion des produits de corrosion des armatures traditionnelles. Nous présentons ici une revue technique de cette solution de protection anticorrosion en essayant d’éclaircir certains freins à cette innovation à partir des résultats obtenus dans notre laboratoire : la résistance à la corrosion des aciers inoxydables est-elle notablement supérieure dans le béton à celle d’un acier standard ? Quel est le risque de corrosion par couplage galvanique entre un acier standard et un acier inoxydable dans le béton ? Quelles nuances choisir en fonction des classes d’exposition du béton ? Des exemples de réalisation avec ce type de matériau seront aussi abordés.
Abstract
The stainless steel reinforced concrete can constitute in certain severe environments (bridge in seaside, ...) an interesting solution for the problem of cracking of concrete by the expansion of corrosion products of the traditional reinforcements. We present here a technical-economic review of this solution of anti-corrosion protection while trying to clear up certain brakes with this innovation starting from results obtained in our laboratory: is the corrosion resistance of the stainless steels really higher in the concrete than that of a carbon steel? Which is the risk of corrosion by galvanic coupling between a standard steel and a stainless steel in the concrete? Which grades to choose according to the classes of exposure? The examples of realization with this type of material are also approached.
Mots clés : Acier inoxydable / corrosion par piqûres / béton armé / durabilité / couplage galvanique
Key words: Stainless steel / pitting corrosion / concrete / durability / galvanic coupling
© EDP Sciences, 2011
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.